INDICATOR BULB TEST
(1)
Unplug right/left indicator bulb from socket.
(2)
Set multimeter to ohms position.
NOTE
A reading of infinity indicates
an open circuit.
(3)
Connect multimeter leads to bulb terminals
and check multimeter for continuity.
WARNING
Jewelry can catch on equipment and
cause injury or short across electrical
circuit and cause severe burns or
electrical
shock.
Remove
rings,
bracelets, watches, necklaces, and any
other Jewelry before working around HET
Tractor.
WIRE NO. 1001/1002 TEST
(1)
Turn ENGINE switch to ON
position.
(2)
Place turn signal switch in
right/left turn position.
(3)
Place positive (+) probe of
multimeter on wire no.
1001/1002 at indicator light.
(4)
Place negative (-) probe of
multimeter on ground and look
for 10-14 volts on multimeter.
(5)
Place turn signal in off position.
(6)
Turn ENGINE switch to OFF
position.
Change 2 2-545.1
|