CONTINUITY TEST
CAUTION
Electrical power must be disconnected from circuit before
continuity can be checked Failure to comply may result in
damage to test equipment or electrical system.
(1)
Disconnect wiring from components at each end of wire
(2)
Set multimeter to ohms position.
NOTE
A reading of infinity indicates an open circuit.
(3)
Connect multimeter leads to each end of wire and check
multimeter for continuity.
NOTE
Any reading besides infinity indicates a grounded wire.
(4) Remove multimeter lead from one end of wire and
connect to chassis ground.
TM 9-2320-360-20-1
WARNING
Jewelry can catch on equipment and
cause Injury or short across electrical
circuit and cause severe burns or
electrical shock. Remove rings, bracelets,
watches, necklaces, and any other jewelry
before working around HET Tractor.
WIRE NO. 1049 VOLTAGE
TEST
(1)
Turn ENGINE switch to ON
position
(2)
Place headlights switch in the on
position.
(3)
Place positive (+) probe of
multimeter on wire no. 1049 at
HEAD LTS relay.
(4)
Place negative (-) probe of
multimeter on ground and look for
10-14 volts on multimeter.
(5)
Place headlights switch in the off
position.
(6)
Turn ENGINE switch to OFF
position.
Check ground wire no. 1435 from HEAD LTS.
relay for loose connections or damage.
WIRE NO. 1927 VOLTAGE TEST
(1)
Turn ENGINE switch to ON position.
(2)
Place headlights switch in the on
position.
(3)
Place positive (+) probe of multimeter
on wire no. 1927 at HEAD LTS. relay.
(4)
Place negative (-) probe of multimeter
on ground and look for 10-14 volts on
multimeter.
(5)
Place headlights switch in the off
position.
(6)
Turn ENGINE switch to OFF position.
Change 2 2-523
|