TM 9-2320-360-20-1
Table 2-1. Preventive Maintenance Checks and Services (Cont)
ITEM TO BE
NOT FULLY
ITEM
INTERVAL
CHECKED OR
PROCEDURE
MISSION
NO.
SERVICED
CAPABLE IF:
NOTE
Engine must be running to perform
this test.
6
Semi-
AIR INTAKE
a.
Check AIR CLEANER RESTRICTION
annually
indicator (1). Press reset button if
indicator reads greater than 15 (in
yellow or red area). Service air
cleaner (2) (para 4-2) if indicator still
reads greater than 15 (in yellow or red
area) and will not reset.
b.
Check hoses (3) and ducting (4) for
b.
Any cracks or
cracks, leaks, or chafing and loose or
tears are in
missing mounting hardware. Tighten
ducting or
loose connections. Replace damaged
hose. Any
parts (para 4-3/4-4).
hardware is
missing.
2-22
|