TM 9-2320-360-20-1 NOTE The following flow chart should only be used     if     DDEC     troubleshooting     was started on p. 2-80 and you were referred here. CONTINUITY TEST (1) Turn ENGINE switch OFF. (2) Disconnect engine harness connector at ECM. (3) Read resistance between sockets S1 and S2 of engine harness connector. CONTINUITY TEST (1) Remove ECM (para 7-29) (2) Disconnect SRS connector. (3) Read resistance between sockets S1 and S2 on engine harness connector. (4) Read resistance between sockets S1 and ground, then between S2 and ground. CAUTION Use    jumper    wire    only    between terminals    indicated.        Failure    to comply   may   result   in   damage   to DDEC components or wiring. CONTINUITY TEST (1) Disconnect SRS connector and install a jumper wire between sockets A and B of SRS harness connector. (2) Read resistance between sockets S1 and S2 on engine harness connector. 2-217