TM 9-2320-360-20-1 NOTE The  following  flow  chart  should  only be used if DDEC troubleshooting was started   on   p.   2-80   and   you   were referred here. (1) Turn ENGINE switch OFF and disconnect TBS connector. (1.1)  Clack on “Alarms Clear" to clear alarms screen. (2) Start and run engine at idle. (3) Read active codes. CAUTION Use jumper wire only between terminals indicated.  Failure to comply may     result     in     damage     to     DDEC components or wiring. CONTINUITY TEST (1) Turn ENGINE switch OFF. (2) Install a jumper wire between pins A and B of TBS harness connector. (3) Disconnect engine harness connector at ECM. (4) Read resistance between sockets P1 and Y2 on engine harness connector. Change 2  2-175