TM 9-2320-356-BD
Option 3:
High-Pressure Line Repair with a Cap.
Procedural Steps:
1.
Disconnect broken hose from source.
2.
Install an adapter in place of hose.
3.
Coat threads of adapter with sealing compound.
4.
Install cap on adapter.
5.
Record the BDAR action taken.
When the mission is completed, as soon as
practicable, repair using standard maintenance procedures.
Option 4:
High-Pressure Line Repair Using Flattened Tube End.
Procedural Steps:
1.
Remove broken tube, if necessary.
2.
Flatten about 6 inches of tubing near break.
3.
Fold flattened portion of tube over twice.
4.
Install repaired tube if removed.
5.
Record the BDAR action taken.
When the mission is completed, as soon as
practicable, repair using standard maintenance procedures.
3-33
|