|
|
274
TM 9-2320-312-24-2
Troubleshooting Section
A second programmable parameter "Fast Idle RPM
#2" provides a second engine rpm set speed. The
ECM will increase the engine speed from low idle to
the engine speed that is programmed in the "Fast
Idle RPM #1" parameter when the fast idle switch
is pressed and then released. The ECM will set the
engine speed to the rpm that is programmed in the
"Fast Idle RPM #2" parameter when the fast idle
switch is pressed and then released again.
Input 18 (terminal 40) is used as a dedicated switch
input for fast idle operation. This feature does not
require an input selection to be programmed to
enable the switch input. A momentary connection
between terminal 40 and a sensor common will
initiate the fast idle operation. The "Fast Idle RPM
#2" and/or "Fast Idle RPM #1" parameters must
be programmed to the desired engine operating
speeds.
The engine rpm set speed will not be maintained if
any of the following actions occur:
g00770407
Illustration 106
The service brake is depressed.
The clutch pedal is depressed.
The neutral switch indicates that the transmission
is in gear.
An optional fast idle lamp can be connected to
output 9 in order to indicate when fast idle is in
operation. When the "Truck Manufacturer" parameter
is configured to "Other", the "Output #9" parameter
must be programmed to "Fast Idle Lamp" to enable
the lamp operation. If the "Output #9" parameter
is programmed to "Wait to Start Lamp", the lamp
will turn on when the air inlet heater is active. When
the "Truck Manufacturer" parameter is configured to
"GM", output 9 can only be used as a fast idle lamp
output, and no programming is necessary.
g00770414
Illustration 107
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |