264
TM 9-2320-312-24-2
Troubleshooting Section
Results:
OK Verify that the repair eliminates the problem.
Clear the logged diagnostic codes. STOP.
Not OK
Repair: Repair the engine harness connector.
STOP.
Test Step 7. Check the Operation of the
ECM by Creating Open and Short Circuits
at the ECM Connector.
g00767376
Illustration 97
Engine harness connector
A short circuit diagnostic code should be active
A. Turn the ignition key switch to the OFF position.
when the jumper wire is installed.
B. Disconnect the Connector for the ECM harness.
Note: If access to the ECM connector is limited, it
Thoroughly inspect both halves of the connector
may be helpful to connect a breakout T to the ECM
for signs of corrosion or moisture.
connector. This will allow the jumper wire to be
inserted into the breakout T. Ensure that the jumper
C. Turn the ignition key switch to the ON position.
wire is inserted into the breakout T and that the full
Monitor the "Active Diagnostic Code" screen.
wiring harness is attached.
Wait at least 15 seconds for activation of the
code.
Refer to Illustration 97 for the engine harness
connector P2.
An open circuit diagnostic code should be active
for the suspect sensor.
Expected Result:
Note: When the engine harness is disconnected, all
Open circuit diagnostic codes are active when the
of the open circuit diagnostic codes for the pressure
jumper is removed. Short circuit diagnostic codes
sensors will be active. This is normal. Disregard the
are active when the jumper is installed.
diagnostic codes for the pressure sensors.
Results:
D. Turn the ignition key switch to the OFF position.
OK The ECM is working properly. Proceed to
E. Fabricate a jumper wire 150 mm (6 inch) long.
Crimp a Deutsch socket to both ends of the wire.
Test Step 8.
Not OK One of the following conditions exists:
F. Install the jumper wire on the ECM pin terminal.
Insert the jumper wire between the terminal for
The open circuit diagnostic code is not active
the suspect sensor signal and the common
when the harness is disconnected. The short
connection for the engine temperature sensor
circuit diagnostic code is not active when the
(terminal 18).
jumper wire is installed.
|