244
TM 9-2320-312-24-2
Troubleshooting Section
102-03 Boost Pressure Sensor Open Circuit (25)
102-04 Boost Pressure Sensor Short Circuit (25)
164-03 Injection Actuation Pressure Sensor Open
Circuit (15)
164-04 Injection Actuation Pressure Sensor Short
Circuit (15)
108-03 Atmospheric Pressure Sensor Open
Circuit (26)
108-04 Atmospheric Pressure Sensor Short Circuit
(26)
The following background information is related
to this procedure:
The troubleshooting procedures for the diagnostic
codes of each pressure sensor are identical. The
pressure sensors are sensors that have three
terminals. The pressure sensors are active sensors.
Active sensors require supply voltage from the
ECM. ECM connector J2/P2 terminal 2 supplies + 5
volts to terminal "A" of each sensor. ECM connector
J2/P2 terminal 3 is the common connection for the
pressure sensors. The sensor common connection
is shared between all of the pressure sensors. The
common line is connected to each sensor connector
terminal "B". The signal voltage from terminal "C" of
each sensor is supplied to the appropriate terminal
at ECM connector J2/P2.