AC RECEIVER-DRIER REPLACEMENT - CONTINUED
0154 00
REMOVAL - CONTINUED
1.
Loosen fitting nuts (2) and disconnect two receiver-drier hoses (1) from receiver-drier (4).
2.
Loosen and remove two band clamps (3) and receiver-drier (4) from bracket (5) at right side of radiator.
3
2
2
1
1
4
5
INSTALLATION
1.
Position receiver-drier (4) and two band clamps (3) to bracket (5) at right side of radiator. Tighten clamps.
NOTE
Apply refrigerant oil to preformed packings of receiver-drier hoses before they are connected. Do NOT
reuse preformed packings.
2.
Connect two receiver-drier hoses (1) to receiver-drier (4) and tighten fitting nuts (2).
3.
Install fan cycling (trinary) switch (WP 0153 00).
4.
Place battery disconnect switch in ON position.
5.
Charge air conditioning system (WP 0149 00).
6.
Leak test air conditioning system (WP 0057 00).
7.
Lower cab (TM 9-2320-312-10).
END OF WORK PACKAGE