TM 9-2320-312-24-1
HYDRAULIC RESERVOIR REPLACEMENT - CONTINUED
0130 00
INSTALLATION
NOTE
Ensure new preformed packings, coated with hydraulic fluid, are used on hydraulic fittings prior to installa-
tion.
1.
Install drain plug (10), plug (2), tee (3), straight fitting (7), and two elbows (4) to hydraulic reservoir (1).
1
10
WARNING
Use extreme caution when handling heavy parts. Provide adequate support and use assistance during proce-
dure. Failure to follow this warning may result in injury to personnel.
2.
Place hydraulic jack, with a block of wood, centered under hydraulic reservoir (1) to provide support.
3.
Install hydraulic reservoir (1) to left frame rail with four bolts (9) and nuts (8).
8,9
1