TM 9-2320-312-24-1
CAB TILT PUMP ASSEMBLY MAINTENANCE - CONTINUED
0124 00
WARNING
At operating temperature, hydraulic oil is hot. Allow hydraulic oil to cool before disconnecting any hydraulic
lines. Failure to do so could result in injury.
Hydraulic fluid is very slippery. Immediately wipe up any spills. Failure to follow this warning may result in
injury to personnel.
PUMP ASSEMBLY REMOVAL
1.
Raise cover (1) to open pump box (2).
2.
Cut tiedown straps as needed to access wiring. Discard tiedown straps.
1
2
0124 00-2
|