TM 9-2320-312-24-1
NATO SLAVE RECEPTACLE REPLACEMENT - CONTINUED
0118 00
REMOVAL
1.
Remove four bolts (1) and cover (2) from slave receptacle mounting box (3).
1
2
3
2.
Remove two screws (8) to free slave receptacle mounting box (3) from battery box support bracket (9).
NOTE
Tag cables to ensure correct installation.
3.
Remove two screws (4) and lockwashers (5) and disconnect battery cables (6) from slave receptacle (7). Discard lock-
washers.
0118 00-2
|