AIR CLEANER RESTRICTION INDICATOR AND HOSES REPLACEMENT - CONTINUED
0078 00
INSTALLATION - CONTINUED
4.
Route hose (8) to front of cab.
5.
As required, assemble adapter (9) and adapter (10).
6.
Connect hose (8) to adapter (9).
7.
Secure hose (8) with new tiedown straps.
8.
Install hose (7) to adapter (10).
9.
Route hose (7) into cab through opening at front of cab. Secure hose with new tiedown straps.
9
10
7
7
8
10.
Lower cab (TM 9-2320-312-10).
11.
Install hose (7) to back of gauge (3).