TM 9-2320-312-24-1
ETHER COLD START SYSTEM MAINTENANCE - CONTINUED
0077 00
ETHER CYLINDER INSTALLATION
CAUTION
Always use new gasket when replacing ether cylinder. Using an old or worn gasket can cause solenoid valve
to discharge entire contents of cylinder into intake manifold. Failure to follow this caution can result in
severe engine damage.
NOTE
Replacement cylinder comes with a new gasket.
1.
Apply a thin coat of lubricating oil to new gasket (4) and threads of new cylinder (2).
2.
Position gasket (4) and cylinder (2) to solenoid valve (3) and tighten until cylinder stops turning. Hand tighten ONLY.
3.
Tighten clamp (1).
4.
Place battery disconnect switch in ON position. Lower cab (TM 9-2320-312-10).
5.
Turn on ignition (TM 9-2320-312-10). Red indicator light (5) on electronic control relay (7) should be on.
6.
Pass a magnet over RESET AREA (6) on electronic control relay (7). Indicator light (5) will flash to indicate system is
reset, then turn off.
5
6
7
0077 00-3
|