TM 9-2320-312-24-1
PARKING BRAKE CONTROL VALVE REPLACEMENT - CONTINUED
0072 00
INSTALLATION
NOTE
Apply a thin coat of pipe sealing compound to male threads of fittings before connections are made.
1.
Install straight adapter (16) and elbow (17) to valve (5). Install tee (15) to straight adapter.
5
15
17
16
2.
Install two elbows (10) and elbow (6).
3.
Assemble straight adapter (14) to switch (13). Install straight adapter with switch to tee (15).
4.
Connect two wires (11) to switch (13) with two screws (12).
11
10
12
4
13
14
15
6
0072 00-4
|