TM 9-2320-312-24-1
DUAL AIR PRESSURE GAUGE AND LOW AIR PRESSURE SWITCHES
REPLACEMENT - CONTINUED
0071 00
REMOVAL - CONTINUED
11.
Remove two nuts (17), starwashers (18), bracket (19), two nuts (20), starwashers (21), and gauge (15) from right-side
instrument panel (2).
17,18
20,21
20,21
2
15
15
19
INSTALLATION
NOTE
New dual air pressure gauge comes with new mounting hardware.
Apply a thin coat of pipe sealing compound to male threads of fittings before connections are made.
1.
Install gauge (15) to right-side instrument panel (2) with two starwashers (21), nuts (20), bracket (19), two starwashers
(18), and nuts (17).
2.
Install elbow (14) and tee (13) to valve (15).
3.
Install switch (8) and elbow (12) to tee (13).
4.
Install tee (16) to valve (15).
5.
Install switch (4) and straight adapter (9) to tee (16).
6.
Connect air line (11) to elbow (12).
7.
Connect air line (10) to straight adapter (9).