0058 00
REMOVAL - CONTINUED
3.
Gently pull out on AC core (4) to gain access to two screws (6).
4.
Remove two screws (6) and mounting plate (7) with switch (8) from expansion valve (5).
6
5
4
8
7
5.
Tag and disconnect two heater/AC unit connectors (10) from switch (8).
NOTE
Note how deep tube is installed in AC core.
6.
Remove switch sensor tube (9) from evaporator (4).
7.
Remove two nuts (11), screws (12), and switch (8) from mounting plate (7).