TM 9-2320-312-24-1
HEATER/AC CONTROLS REPLACEMENT - CONTINUED
0055 00
INSTALLATION - CONTINUED
4.
Connect cable (3) to shaft of valve (6) and secure with retainer nut (2).
5.
Secure cable (3) to valve (6) with clamp (4) and screw (5).
6.
Rotate knob (11) on instrument panel and verify cable (3) functions properly to open and close valve (6).
7.
Close heater/AC unit access door (1).
4
3
2
5
1
6
8.
Install lower-right instrument panel (9) with three screws (10).
9.
Install top-front instrument panel (7) with 14 screws (8).
8
7
10
9
10.
Place battery disconnect switch in ON position.
END OF WORK PACKAGE