TM 9-2320-312-10
ENGINE AIR CLEANER SERVICE - CONTINUED
0015 00
SERVICE - CONTINUED
WARNING
Compressed air used for cleaning purposes should never exceed 30 psi (207 kPa). Wear protective clothing
(goggles/shield, gloves, etc.) and use caution to avoid injury to personnel.
6.
Use compressed air, directed along pleats from the inside out, to remove dirt and dust from filter element.
7.
Inspect filter element after cleaning. Notify Unit Maintenance to obtain replacement filter element if damage is found.
8.
Install filter element inside housing, with smaller closed end facing outward.
9.
Install cover on housing and secure with three clamps
COVER
CLAMPS
AIR CLEANER
HOUSING
10. Reset air cleaner restriction indicator on instrument panel (WP 0004 00) by pressing yellow reset button at bottom of
gauge.
11. Start engine (WP 0005 00).
12. Ensure yellow band on air cleaner restriction indicator is in green zone on gauge. If gauge shows yellow band in red zone,
notify Unit Maintenance
END OF WORK PACKAGE
0015 00-3/4 Blank
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |