Table 1. Preventive Maintenance Checks and
Services (PMCS) for M878A2 - Continued.
LOCATION
ITEM TO
ITEM
CHECK/
NOT FULLY MISSION
NO.
INTERVAL
SERVICE
PROCEDURE
CAPABLE IF:
WARNING
Ether fuel is extremely flammable and toxic. DO NOT smoke and make
sure you are in a well-ventilated area away from heat, open flames or
sparks. Wear eye protection. Avoid contact with skin and eyes and avoid
breathing ether fumes. If fluid enters or fumes irritate the eyes, wash
immediately with large quantities of clean water for 15 minutes. Seek
medical attention immediately if ether is inhaled or causes eye irritation.
Failure to follow this warning may cause death or serious injury to person-
nel.
a. Check for loose connections and a. Damage or leakage is evident.
47
Monthly
Ether Cold
Start System
damage to lines, fittings, and cylin-
der. Be alert for odor of leaking
ether.
b. With ignition on, check that red indi- b. If red indicator light is on, notify
cator light on ether electronic con-
Unit Maintenance.
trol relay is not on.
ETHER FUEL
CYLINDER
INDICATOR
LIGHT
0012 00-27