TM 9-2320-312-10
Table 1. Preventive Maintenance Checks and
Services (PMCS) for M878A2 - Continued.
LOCATION
ITEM TO
ITEM
CHECK/
NOT FULLY MISSION
NO.
INTERVAL
SERVICE
PROCEDURE
CAPABLE IF:
29
After
Hydraulic
a. Check hydraulic filter, reservoir, and a. Class III leaks are evident.
Reservoir
hydraulic hoses for damage and
leaks.
b. With fifth wheel fully lowered, b. Class III leaks are evident.
check level of hydraulic fluid at
hydraulic reservoir sight gauge.
Fluid should be level with FULL
line stenciled on reservoir. Add
hydraulic fluid (Item 7 or 8, WP
opening at top of reservoir. Level
must not exceed line stenciled on
reservoir.
FILL
CAP
SIGHT
GAUGE
HYDRAULIC
RESERVOIR
HYDRAULIC
HOSES
HYDRAULIC
HYDRAULIC
FILTER
HOSES
0012 00-15
|