(154) Position sensor plate (183) with two clamps on hook arm (51) as shown.
(155) Mark line around sensor plate (183) on hook arm (51).
(156) Remove two clamps and sensor plate (183) from hook arm (51).
WARNING
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors,
and are harmful to skin and clothing. To avoid injury or death, keep away from open fire
and use in well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or
clothing, wash immediately with soap and water.
NOTE
Mix epoxy according to directions on package.
(157) Mix epoxy supplied with CHU kit and
apply to sensor plate (183) and hook
arm (51).
NOTE
Epoxy takes approximately 15 minutes to
cure.
(158) Clamp sensor plate (183) to hook
arm (51) in position marked until
cured.
(159) Remove clamps from hook arm (51).
(160) Prime and paint area as necessary
(TM 43-0139).