TM 9-2320-304-14&P
5-180
Direct Support and General Support Maintenance (Cont)
5-35. LOAD HANDLING SYSTEM (LHS) DIRECTIONAL CONTROL VALVE
REPLACEMENT (CONT).
b. Installation.
(1) Apply hydraulic oil to five preformed packings (1).
(2) Install five preformed packings (1) on directional control valve (2).
(3) Install directional control valve (2) on hydraulic manifold (3) with four screws (4).
(4) Install two connectors (5) with screws (6).
WARNING
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors,
and are harmful to skin and clothing. To avoid injury or death, keep away from open fire
and use in well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or
clothing, wash immediately with soap and water.
(5) Apply sealing compound to heads of screws (6).
(6) Install LHS control box cover (7) on
bracket (8) with four lockwashers (9)
and screws (10).
(7) Connect two hose quick disconnects (11)
on main junction box quick
disconnects (12).
c. Follow-on Maintenance.
(1) Start engine (TM 9-2320-279-10).
(2) Operate LHS (Para 2-9).
(3) Check for oil leaks (TM 9-2320-279-10).
(4) Shut OFF engine (TM 9-2320-279-10).
(5) Check hydraulic oil reservoir level
(TM 9-2320-279-20).
(6) Remove wheel chocks
(TM 9-2320-279-10).
END OF TASK
|