TM 9-2320-304-14&P 5-146 Direct Support and General Support Maintenance (Cont) 5-30.    LOAD HANDLING SYSTEM (LHS) MAIN HYDRAULIC PRESSURE ADJUSTMENT (CONT). NOTE · Hydraulic oil in reservoir must be 120_F (49_C) ±5to obtain proper pressure reading for HEMTT LHS. · Hydraulic oil in reservoir must be 105_F (41_C) ±5_. · Engine must be at full throttle to obtain proper pressure reading on HEMTT LHS with CHU. (10)   Soldier A, start engine (TM 9-2320-279-10), engage PTO (TM 9-2320-279-10), put hydraulic selector switch (9) in MAN H.A. (Para 2-9) and move joystick (10) to LOAD position. Soldier B, record pressure. (11)   Shut off engine (TM 9-2320-279-10). (12)   Repeat steps (7) thru (11) until pressure setting is correct. Change 1