TM 9-2320-304-14&P
5-128
Direct Support and General Support Maintenance (Cont)
5-26. LOAD HANDLING SYSTEM (LHS) COMPRESSION FRAME REPAIR (CONT).
a. Removal.
WARNING
The LHS hydraulic system operates at oil pressures up to 1,725 psi (11 894 kPa). Never
disconnect any hydraulic line or fitting without first dropping pressure to zero. Failure to
comply may result in serious injury or death to personnel.
NOTE
·
Tag and mark all hoses prior to removal.
·
Left side and right side procedures are the same. Left side is shown.
Disconnect hoses 2588, 2888, 2889, and 2892 on the right side.
·
Cap and plug all hoses and tubes prior to removal.
(1) Disconnect hoses 2887 (1), 2666 (2), and 2890 (3) from three adapters (4) at front of compression
frame (5).
(2) Disconnect hose 2891 (6) from adapter (7) at front of compression frame (5).
|