TM 9-2320-304-14&P
5-88
Direct Support and General Support Maintenance (Cont)
5-19. LOAD HANDLING SYSTEM (LHS) MAIN WIRE HARNESS REPLACEMENT
(CONT).
(5)
Install four cushion clips (10) on main wire harness (11).
WARNING
Adhesives, solvents, and sealing compounds can burn easily, give off harmful vapors, and
are harmful to skin and clothing. To avoid injury or death, keep away from open fire and
use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or
clothing, wash immediately with soap and water.
NOTE
Do not apply sealing compound to upper screw, until cushion clips have been installed.
(6) Apply sealing compound to threads of
screws (12).
(7) Install four cushion clips (10) with four
washers (13), four lockwashers (14), and
four screws (12) to compression frame
tube (15) at inside of left compression
frame rail (2).
(8) Using cable ties, attach LHS main wire
harness (11) to compression frame
tube (15).
(9) Using cable ties, attach LHS main wire
harness (11) to main frame hoses (16)
and main frame tubes (17).
|