TM 9-2320-304-14&P
4-234.2
Organizational Maintenance Instructions (Cont)
4-53.1 CONTAINER HANDLING UNIT (CHU) CONTAINER GUIDE REPAIR (CONT).
b. Disassembly.
NOTE
·
Perform step (1) if wire rope or lock
pin is damaged.
·
There are two lock pins on container
guide. Left side is shown.
(1)
Remove two swaging sleeves (1), wire
rope (2), and lock pin (3) from container
guide (4). Discard wire rope and
swaging sleeves.
c. Cleaning/Inspection.
WARNING
·
Drycleaning Solvent (P-D-680) is TOXIC and flammable. Wear protective goggles,
face shield, and gloves; use only in a well-ventilated area; avoid contact with skin,
eyes, and clothes; and do not breathe vapors. Keep away from heat or flame. Never
smoke when using solvent. The flashpoint for Type III Drycleaning Solvent is 200_F
(93_C). Failure to do so may result in injury or death to personnel.
·
If personnel become dizzy while using cleaning solvent, immediately get fresh air
and medical help. If solvent contacts skin or clothes, flush with cold water. If
solvent contacts eyes, immediately flush eyes with water and get immediate medical
attention.
(1)
Clean all metal parts with drycleaning solvent.
WARNING
Compressed air used for cleaning purposes shall not exceed 30 psi (207 kPa). Use only with
effective chip guarding and personal protective equipment (goggles/shield, gloves, etc.), or
injury to personnel may result.
(2)
Dry parts with compressed air.
(3)
Inspect parts for breaks, cracks, burrs, and sharp edges. Look for unusual signs of wear on
container guide.
(4)
Replace all damaged parts.
Change 1
|