TM 9-2320-304-14&P
2-11
Operating Instructions (Cont)
NOTE
·
To reset LHS overload, return load to start position and release joystick switch.
·
When attempting to load/unload Forward Repair System (FRS), manual-mode
procedures must be followed, or LHS overload system will shut down the LHS
system (Para 2-9d and Para 2-9e).
(h) LHS OVER LOAD indicator (4) (yellow) is located on the drivers dash panel and
illuminates whenever main hydraulic relief valve is opened during loading or unloading.
When indicator illuminates, driver will be warned that LHS has reached an overload
condition or that hydraulic system is lifting very near maximum capacity. LHS OVER
LOAD indicator will come on any time main relief valve is cracked open; therefore, load or
unload operation may not come to a complete stop, but indicator will come on momentarily.
This situation would indicate that system is lifting near maximum capacity. If the LHS is
overloaded, the LHS OVER LOAD indicator illuminates and the system is automatically
blocked out. Off-load/on-load flatrack and attempt second operation. If during this second
attempt the LHS shuts down, stop operation and redistribute weight or reduce payload
before attempting load or unload.
Change 1
|