TM 9-2320-304-14&P
4-189
Organizational Maintenance Instructions (Cont)
CAUTION
Carefully remove main junction box cover to avoid pulling out wires; damage to wires may
result.
(2) Loosen four captive screws (5) and main junction box cover (6) from main junction box (7).
NOTE
·
Steps (3) and (4) are for left safe lowering button only.
·
Steps (5) and (6) are for right safe lowering button only.
·
Tag and mark wires prior to removal.
(3) Loosen screw (8) and remove wire
1479 (9) and wire 1479 (10) from
switch (11).
(4) Loosen screw (12) and remove wire
1478 (13) from switch (11).
|