TM 9-2320-304-14&P
4-184.5
Organizational Maintenance Instructions (Cont)
(12)
Position sensor plate (8) with two
clamps on hook arm (7) as shown.
(13)
Mark line around sensor plate (8) on
hook arm (7).
(14)
Remove two clamps and sensor plate (8)
from hook arm (7).
WARNING
Adhesives, solvents, and sealing
compounds can burn easily, can give off
harmful vapors, and are harmful to skin
and clothing. To avoid injury or death,
keep away from open fire and use in
well-ventilated area. If adhesive, solvent,
or sealing compound gets on skin or
clothing, wash immediately with soap and
water.
NOTE
Mix epoxy according to directions on package.
(15)
Mix epoxy and apply to sensor plate (8) and hook arm (7).
NOTE
Epoxy takes approximately 15 minutes to cure.
(16)
Clamp sensor plate (8) to hook arm (7) in position marked until cured.
(17)
Remove clamps from hook arm (7).
(18)
Prime and paint area as necessary (TM 43-0139).
(19)
Install two screws (10),
lockwashers (11), and proximity switch
mount (12) on two clamp halves (13).
(20)
Install CHU proximity switch (14) and
two nuts (15) on proximity switch
mount (12).
Change 1
|