TM 9-2320-304-14&P
4-168.6
Organizational Maintenance Instructions (Cont)
4-33.2 CONTAINER HANDLING UNIT (CHU) WIRE HARNESS REPLACEMENT (CONT).
b. Installation.
NOTE
·
Install cable ties as required.
·
Connector MC189 does not connect to anything. MC189 is installed with the CHU
wiring harness.
(1)
Connect CHU wire harness (1) to main frame proximity switch wire harness (2) at connector
MC185.
(2)
Position CHU wire harness (1), main frame proximity switch wire harness (2), and two MC190
connectors (3) along inside of frame (4).
(3)
Position CHU wire harness (1) with MC188 connector (5) along inside of main frame (6) with
existing wires.
(4)
Position CHU wire harness with MC185A connector (7) along inside of compression frame (8)
with existing wires.
(5)
Connect two MC190 connectors (3) to right and left rear lock limit switches (9).
(6)
Connect MC188 connector (5) to hook arm up proximity switch (10).
(7)
Connect MC186 connector (11) to CHU main frame proximity switch (12).
Change 1
|