Malfunction
Test or Inspection
Corrective Action
TM 9-2320-304-14&P
4-142.2
Organizational Maintenance Instructions (Cont)
4-18. TROUBLESHOOTING INSTRUCTIONS (CONT).
Table 4-3.1. Container Handling Unit (CHU) Troubleshooting (CONT)
CONTAINER HANDLING UNIT (CHU) (CONT)
2. LHS-CHU DOES NOT UNLOAD.
WARNING
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive
electrical circuits, a direct short may result. Damage to equipment and injury or death to
personnel may occur.
Step 1. Check for continuity between connector MC185A, terminal F and terminal G.
If there is continuity between connector MC185, terminal F and terminal G, replace
CHU wiring harness.
Change 1
|