Malfunction
Test or Inspection
Corrective Action
TM 9-2320-304-14&P
4-115
Organizational Maintenance Instructions (Cont)
Table 4-3. Load Handling System (LHS) Troubleshooting (CONT)
LOAD HANDLING SYSTEM (LHS) (CONT)
14. MAIN FRAME DOES NOT UNLOAD IN MANUAL MODE (CONT).
WARNING
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive
electrical circuits, a direct short may result. Damage to equipment and injury or death to
personnel may occur.
Step 10. Check continuity on wire 1435 between main frame up DC valve harness connector termi-
nal 1 and chassis ground.
If there is no continuity, repair wire 1435 or notify DS Maintenance.
|