Malfunction
Test or Inspection
Corrective Action
TM 9-2320-304-14&P
4-82
Organizational Maintenance Instructions (Cont)
4-18. TROUBLESHOOTING INSTRUCTIONS (CONT).
Table 4-3. Load Handling System (LHS) Troubleshooting (CONT)
LOAD HANDLING SYSTEM (LHS) (CONT)
11. LHS DOES NOT OPERATE (CONT).
WARNING
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive
electrical circuits, a direct short may result. Damage to equipment and injury or death to
personnel may occur.
Step 4. Check for continuity between hydraulic selector switch connector MC94 terminal F and
terminal B and also between switch connector MC94 terminal D and MC93 terminal E
with switch in MAN H.A. position.
If there is no continuity, replace hydraulic selector switch (Para 4-31).
|