Malfunction
Test or Inspection
Corrective Action
TM 9-2320-304-14&P
4-40
Organizational Maintenance Instructions (Cont)
4-18. TROUBLESHOOTING INSTRUCTIONS (CONT).
Table 4-3. Load Handling System (LHS) Troubleshooting (CONT)
LOAD HANDLING SYSTEM (LHS) (CONT)
3. LHS OVER LOAD INDICATOR DOES NOT OPERATE (CONT).
WARNING
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive
electrical circuits, a direct short may result. Damage to equipment and injury or death to
personnel may occur.
Step 4. Check for 22 to 28 Vdc on wire 1479 at overload differential pressure switch harness
connector terminal 2 with ENGINE switch in ON position.
If Vdc measurement is below specification, turn ENGINE switch to OFF position
and repair wire 1479 or notify DS Maintenance.
|