Malfunction
Test or Inspection
Corrective Action
TM 9-2320-304-14&P
4-38
Organizational Maintenance Instructions (Cont)
4-18. TROUBLESHOOTING INSTRUCTIONS (CONT).
Table 4-3. Load Handling System (LHS) Troubleshooting (CONT)
LOAD HANDLING SYSTEM (LHS) (CONT)
3. LHS OVER LOAD INDICATOR DOES NOT OPERATE (CONT).
WARNING
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive
electrical circuits, a direct short may result. Damage to equipment and injury or death to
personnel may occur.
Step 2. Check for 22 to 28 Vdc on wire 1726 at LHS OVER LOAD indicator with LHS in transit
position and joystick held in LOAD position and then released.
If there are 22 to 28 Vdc on wire 1726 go to Step 9. of this Fault.
|