Malfunction
Test or Inspection
Corrective Action
TM 9-2320-304-14&P
4-14
Organizational Maintenance Instructions (Cont)
4-18. TROUBLESHOOTING INSTRUCTIONS (CONT).
Table 4-3. Load Handling System (LHS) Troubleshooting (CONT)
LOAD HANDLING SYSTEM (LHS) (CONT)
1. LHS INDICATOR DOES NOT OPERATE (CONT).
WARNING
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive
electrical circuits, a direct short may result. Damage to equipment and injury or death to
personnel may occur.
Step 2. Check for 22 to 28 Vdc on wire 1722 at LHS indicator connector, with ENGINE switch ON
and the hydraulic selector switch in MAN H.A. position.
If there are 22 to 28 Vdc at LHS indicator connector, go to Step 11. of this Fault.
If Vdc measurement is below specification, go to Step 3. of this Fault.
|