TM 9-2320-304-14&P 4-8 Organizational Maintenance Instructions (Cont) 4-16. PMCS TABLE (CONT). Table 4-1. Unit Level Preventive Maintenance Checks and Services (PMCS) (Cont) Location Item No. Interval Item to Check/ Service Procedure Not Fully Mission Capable if: 3 Semi- annual Self-Guided Coupler Check self-guided coupler (1) for cracks, damage, or excessive wear. Replace coupler if cracked or damaged. If radial wear exceeds 3/16 in. (4.76 mm) total, replace coupler before next mission. If axial clearance exceeds 1/32 in. (0.79 mm), measure thickness of washer (2). If washer (2) thickness is under 3/16 in. (4.76 mm), replace washer. If washer thickness is larger than 3/16 in. (4.76 mm), adjust nut (3). Refer to TM 9-2320-279-20. Radial wear exceeds 3/16 in. (4.76 mm). Washer thickness is less than 3.16 in. (4.76 mm).