TM 9-2320-304-14&P
5-258
Direct Support and General Support Maintenance (Cont)
5-43. CONTAINER HANDLING UNIT (CHU) KIT INSTALLATION (CONT).
(174) Position sensor plate (193) with two
clamps on compression frame (192) as
shown.
(175) Mark line around sensor plate (193) on
compression frame (192).
(176) Remove two clamps and sensor
plate (193) from compression
frame (192).
WARNING
Adhesives, solvents, and sealing
compounds can burn easily, can give off
harmful vapors, and are harmful to skin
and clothing. To avoid injury or death,
keep away from open fire and use in
well-ventilated area. If adhesive, solvent,
or sealing compound gets on skin or
clothing, wash immediately with soap and
water.
NOTE
Mix epoxy according to directions on
package.
(177) Mix epoxy supplied with CHU kit and
apply to sensor plate (193) and
compression frame (192).
NOTE
Epoxy takes approximately 15 minutes to
cure.
(178) Clamp sensor plate (193) to
compression frame (192) in position
marked until cured.
(179) Remove clamps from compression
frame (192).
(180) Prime and paint area as necessary
(TM 43-0139).
Change 1
|