Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-303-24-2
HEATING, VENTILATION, AIR CONDITIONING (HVAC) UNIT REPLACEMENT - CONTINUED
0298 00
INSTALLATION - CONTINUED
18.
Charge system with refrigerant (WP 0297 00).
19.
Add refrigerant oil to compressor to replace that which was lost during system discharge (WP 0301 00).
WARNING
Refrigerant R-134a air conditioning systems should not be pressure tested or leak tested with compressed
air. Combustible mixtures of air and R-134a may form, resulting in a fire or explosion, which could cause
personnel injury or death.
20.
Leak test air conditioner system (WP 0218 00).
21.
Install compartment (12) into dash (9) and secure with three nuts (14) and spring washers (15).
22.
Install top panel (11) to compartment (12) and secure with two screws (10).
11
10
9
12
13
14,15
23.
Position cover (8) on dash (9) and secure with seven screws (7).
7
8
9
7