AIR CONDITIONING SYSTEM REFRIGERANT (R-134A) MAINTENANCE - CONTINUED
0297 00
EVACUATING/RECYCLING
NOTE
System must have been recovered and compressor filled with correct amount of refrigerant oil. Replace
receiver-dryer if system is opened.
1.
Wearing protective goggles and non-leather gloves, attach recovery/recycling station's hoses to valves.
NOTE
Push down firmly on hose connectors until a clicking sound is heard. This will ensure coupler is locked.
a.
Ensure recovery/recycling station's valves are closed.
b.
Connect red high-side hose to discharge service valve.
c.
Connect blue low-side hose to suction service valve.
d.
Turn knob clockwise on each coupler to open shrader valves.
2.
Follow recovery/recycling manufacturer's instructions and evacuate/recycle refrigerant system.
0297 00-3