TM 9-2320-303-24-2
EQUALIZING BEAM REPAIR - CONTINUED
0288 00
INSTALLATION
CAUTION
Use press plate or support equalizing beam bore square on press bed. Failure to do so could result in bent
beam, requiring replacement.
NOTE
Installation of bushings requires 50-ton or larger press.
1.
Coat all metal surfaces of bushings with GAA.
2.
Using suitable press, install adapter and press adapter. Install new center bushing (3) in equalizing beam (2).
3.
Using suitable press, install adapter clamp, plate clamp, and press adapter. Clamp installing adapter clamp to new bush-
ing (1). With plate clamp and press adapter assembled as shown, press bushing (1) until completely installed and center
in equalizing beam (3).
1
3
2
1
4.
Repeat steps 2 and 3 for other bushing (1).
PRESS
ADAPTER
PLATE
1
206457
CLAMP
206459
2
1
INSTALLING
ADAPTER
CLAMP
42052
5.
Install equalizing beam (WP 0287 00).
END OF WORK PACKAGE
0288 00-2
|