TM 9-2320-303-24-2
AIR DRYER REPAIR - CONTINUED
0262 00
ASSEMBLY - CONTINUED
NOTE
Perform steps 23 through 26 to install REGENERATION VALVE ASSEMBLY.
23.
Apply thin coat of grease to new O-ring (10).
24.
Install filter (9) and O-ring (10) to housing (7).
25.
Position rubber diaphragm (4) to air dryer (3) with lip of diaphragm in groove of air dryer. Do not apply grease.
26.
With lip of cap (5) facing away from air dryer (3), install cap, spring (6), and housing (7) with four screws (8). Tighten
screws to 53 lb-in (6 Nm).
3
4
5
6
7
10
9
8