AIR CONDITIONER THERMOSTATIC SWITCH REPLACEMENT - CONTINUED
0214 00
REMOVAL - CONTINUED
2.
Disconnect wiring harness connector (7) from thermostatic switch (6).
3.
Remove four screws (8) and heater core cover (3).
NOTE
Mark thermostatic switch sensor tube at entry point in evaporator to aid in installation.
4.
Remove two screws (5) and thermostatic switch (6) with sensor tube (4) attached.
4
5
3
5
8
7
6
INSTALLATION
1.
Transfer measurement from old sensor tube (4) to new sensor tube, if installing a new thermostatic switch (6).
CAUTION
Use care when installing thermostatic switch sensor tube in evaporator. Using too much force will cause
tube to bend or kink.
2.
Carefully insert sensor tube (4) into evaporator to a depth equal to mark on sensor tube.