TM 9-2320-303-24-1
PARKING BRAKE AND TRAILER AIR SUPPLY VALVE REPLACEMENT- CONTINUED
0150 00
INSTALLATION
WARNING
Make sure all air lines and fittings are clear of debris. Make sure excess pipe sealant compound does not
enter air lines or fittings. Failure to do so could result in equipment failure and/or injury to personnel.
Sealant compounds can burn easily, give off harmful vapors, and are harmful to skin and clothing. To
avoid injury or death, keep away from open fire and use in well-ventilated area. If sealant compound
gets on skin or clothing, wash immediately with soap and water.
1.
Coat threads with pipe sealant compound and install plug (13), tee (7), adapter (8) and five elbows (6) in valve (12).
2.
Install valve (12), four washers (10), and four screws (11).
3.
Connect six tubes (9) to valve (12).
4.
Install panel (4) and five torx screws (5).
5.
Install defroster vent (2), cover (3), and six torx screws (1).
1
5
4
2
3
END OF WORK PACKAGE
0150 00-3/(0150 00-4 blank)
|