TM 9-2320-303-24-1
REAR QUICK-RELEASE VALVE REPLACEMENT - CONTINUED
0148 00
INSTALLATION
WARNING
Make sure all air lines and fittings are clear of debris. Make sure excess pipe sealant compound does not
enter air lines or fittings. Failure to do so could result in equipment failure and/or injury to personnel.
Sealant compounds can burn easily, give off harmful vapors, and are harmful to skin and clothing. To
avoid injury or death, keep away from open fire and use in well-ventilated area. If sealant compound
gets on skin or clothing, wash immediately with soap and water.
1.
Coat threads with pipe sealant compound and install pipe nipple (8), two-way check valve (4), two connectors (3), two
tees (9), and two elbows (7) in quick-release valve (12).
2.
Install quick-release valve (12), two washers (2), two screws (1), two washers (11), and two new locknuts (10).
3.
Connect four hoses (6) and two tubes (5) to quick-release valve (12).
END OF WORK PACKAGE