TM 9-2320-303-24-1
FRONT QUICK-RELEASE VALVE REPLACEMENT - CONTINUED
0147 00
REMOVAL - CONTINUED
2.
Remove two locknuts (8), two washers (7), two screws (4), two washers (5), and quick-release valve (2) from cross-
member (6). Discard locknuts.
3.
Remove three elbows (3) from quick-release valve (2).
3
4
5
6
7
8
3
2
INSTALLATION
WARNING
Make sure all air lines and fittings are clear of debris. Make sure excess pipe sealant compound does not
enter air lines or fittings. Failure to do so could result in equipment failure and/or injury to personnel.
Sealant compounds can burn easily, give off harmful vapors, and are harmful to skin and clothing. To
avoid injury or death, keep away from open fire and use in well-ventilated area. If sealant compound
gets on skin or clothing, wash immediately with soap and water.
1.
Coat threads with pipe sealant compound and install three elbows (3) in quick-release valve (2).
2.
Install quick-release valve (2), two washers (5), two screws (4), two washers (7), and two new locknuts (8) on cross-
member (6).
0147 00-2
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |