TM 9-2320-303-24-1
CONSTANT AIR JUNCTION BLOCK REPLACEMENT - CONTINUED
0142 00
REMOVAL - CONTINUED
NOTE
Tag all tubes, connectors and plugs prior to disconnecting/removal to aid in installation/connecting.
2.
Disconnect three tubes (11).
3.
Remove two nuts (9), washers (6), screws (5), and constant air junction block (8).
4.
Remove connector (10), two elbows (12), and three plugs (7) from constant air junction block (8).
7
6
5
8
9
10
7
11
12
9
11
12
11
7
INSTALLATION
WARNING
Adhesives and sealing compounds can burn easily, can give off harmful vapors, and are harmful to skin
and clothing. To avoid injury or death, keep away from open fire and use in a well-ventilated area. If
adhesives or sealing compound gets on skin or clothing, wash immediately with soap and water.
Ensure all air lines and fittings are clear of debris and excess pipe sealing compound does not enter air
lines or fittings. Failure to follow this warning could result in injury to personnel or damage to equip-
ment.
1.
Coat threads with pipe sealing compound and install three plugs (7), two elbows (12), connector (10), in constant air
junction block (8).
0142 00-2
|