TM 9-2320-303-24-1
PRIMARY II AIR TANK AND FITTINGS REPLACEMENT - CONTINUED
0130 00
INSTALLATION
NOTE
Perform steps 1 through 3 only if fittings have been removed from air tank.
Install automatic drain valve (WP 0133 00) if equipped.
1.
Install two mounting brackets (3), two screws (1), and two nuts (2).
WARNING
Make sure all air lines and fittings are clear of debris. Make sure excess pipe sealant compound does not
enter air lines or fittings. Failure to do so could result in equipment failure and/or injury to personnel.
Sealant compounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing.
To avoid injury or death, keep away from open fire and use in well-ventilated area. If sealant compound
gets on skin or clothing, wash immediately with soap and water.
2.
Coat pipe threads of new drain valve (8), new plug (10), and three new elbows (7) with pipe sealant compound.
3.
Install drain valve (8), plug (10), and three elbows (7) in new air tank (9).
4.
Install air tank (9), four washers (4), and four new locknuts (5).
5.
Connect three tubes (6) to air tank (9).
6.
Start vehicle and check for leaks (TM 9-2320-303-10).
7.
Install spare tire (TM 9-2320-303-10).
END OF WORK PACKAGE
0130 00-3/(0130 00-4 blank)
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |